Add medical equipment to get started

Get the best price — we usually reply within minutes (Mon–Sat, 9am–9pm)
Get instant answers about specifications, pricing, and availability
Note: All specifications are subject to manufacturer standards. Contact our team for detailed technical documentation and compliance certificates.
Contec CMS9000 6 Parameter Patient Monitor-SPO2,PR,NIBP,RESP,TEMP,ECG w/ Printer Specifications: ECG Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-lead, 1-lead Gain: 2,5mm / mV, 5,0mm / mV, 10mm / mV, 20mm / mV, 40mm / mV Scanning speed: 12,5mm / s, 25mm / s, 50mm / s HR: Measurement and alarm range: 15~350bpm Precision: ±1% or ±1bpm, whichever is higher alarm accuracy: ± 2bpm Resolution: 1bpm ST-segment monitoring: measurement and alarm range: -2.0mV~+2.0mV Precision: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is higher Other range: unspecified arrhythmic analysis: ASYSTOLE, VFIB / VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACH RESPIRATION Method: R-F(RA-LL) Respiration rate: measurement and alarm range: 0~150rpm Resolution: 1 rpm Respiration accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scanning speed: 6.25 mm / s, 12.5 mm / s, 25 mm / s. NIBP Method: Oscillometry Mode: Manual / AUTO / Continuous Measurement period in AUTO mode: 1/2/3/4/5/10/15/60/90/120/240/480/960 minutes Continuous mode measurement interval: 5 minutes Measurement and warning range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff stress accuracy: ±3 mmHg Measurement accuracy: maximum mean deviation: ±5 mmHg Maximum standard deviation: 8 mmHg Over-pressure protection: adult mode SpO2 Measurement and warning range: 0 ~ 100 percent resolution: 1 percent accuracy of measurement: 70 percent ~100 percent: ±2 percent; 0 percent ~69 percent: unspecified. PR Measuring and alarm range: 30 ~ 250 bpm Measuring accuracy: ±2 bpm or ±2%, whichever is higher TEMP Channel: dual-channel Measurement and alarm range: 0 ~ 50ºC Resolution: 0.1 ºC Accuracy: ±0.1 ºC EtCO2 Method: Sidestream or Mainstream CO2 measurement range: 0~150mmHg CO2 resolution: 0~69mmHg: 0.1mmHg 70~150mmHg CO2 accuracy: 0.25mmHg CO2 accuracy: 0~40mmHg: ±2mmHg 41~70mmHg: ±5 percent 71~100mmHg: ±8 percent 101~150mmHg CO2 accuracy: ±10 percent AwRR accuracy: ±1 rpm Apnea alarm: yes. IBP Channel: dual-channel label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and warning range: -10~300 mmHg Resolution: 1 mmHg Precision: ±2% or 1 mmHg, whichever is higher Power supply: AC 100-240V, 50/60Hz Safety classification: Class I, CF defibrillation-proof component added. Accessories SpO2 test for adult fingertips (5-pin) NIBP adult cuff NIBP extension pipe ECG lead cable ECG electrode Temperature probe Power cord Physical characteristic Dimension: 319 mm(L) × 161 mm(W) × 269 mm(H) Weight: 3.6 Kg Contec CMS9000 6 Parameter Patient Monitor-SPO2,PR,NIBP,RESP,TEMP,ECG w/ Printer Description: Clinic ICU Multipara Patient Monitor can monitor parameters such as ECG, RESP, SpO2, PR, NIBP, TEMP, etc. CMS7000 integrates parameter measurement module, display, and recorder into one device to create a compact and portable device. At the same time, the built-in replaceable battery provides patient movement comfort. Functions Regular parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP ECG Heart rate(HR) ECG waveform Arrhythmia and ST-segment measurement RESP Respiration rate(RR) Respiration waveform SpO2 Pulse oxygen saturation(SpO2) Plethysmogram(PLETH) waveform Pulse rate(PR) Bar graph. NIBP Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MEAN) TEMP T1, T2, TD It has many features, such as audible and visual warning, trend data storage and performance, NIBP measurement, alarm event labeling, and drug concentration estimation, etc. Features 1” TFT LCD screen,15-language interface (Simplified Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech). Quiet, energy-saving and safe fanless model that reduces the potential for cross-infection. All-round adult, pediatric and neonatal care. OxyCRG, pattern with generic GUI. view a single screen with an up to8-channel waveform. Display on a single screen 7-lead ECG waveform and ECG phase feature. Adopt electronic SpO2 technology, anti-motion, and anti-ambient light interference, and measurement under poor filling conditions. Feature for evaluating HRV. NIBP measuring mode: manual / AUTO / continuous processing for NIBP data in the 4800-group. Analysis of all criteria for 71 warning events and 60 alarm event Calculation of the concentration of drugs and functions of the titration table. Print one-key data from the trend table. Connect 3 G, WiFi or wired to the Central Monitoring System.
Contec, Medical Equipment, China Quality, Hospital Machines.
Browse the full Hospital Machines collection for more options, or compare prices across brands before you buy.
Yes. MediportBD is an authorised distributor of Contec in Bangladesh. All products are DGDA registered and CE certified, with full documentation available for hospital procurement and tenders.
This product comes with full manufacturer warranty, typically 1–3 years depending on the equipment type. Extended warranty and annual maintenance contracts (AMC) are available for most items.
The retail price of Contec CMS9000 6 Parameter 12” Patient Monitor-SPO2,PR,NIBP,RESP,TEMP,ECG w/ Printer in Bangladesh is Contact for Price. B2B buyers (hospitals, clinics, diagnostic centres) receive 8–30% bulk discount depending on order volume and credit terms.
Yes, installation and staff training are included for diagnostic and hospital equipment in Dhaka metro. For other regions, installation is available at nominal charges.
Delivery within Dhaka takes 1–2 business days, and 3–5 business days for other cities. Cold-chain and temperature-controlled delivery is available for reagents and temperature-sensitive items.